North Kansas City, MO Residential HVAC & Plumbing Services
LBA Services was started by people just like you who want and insist on high quality and reliable service. In North Kansas City, MO and throughout the Kansas City area, we treat each family and home as if it were our own. That includes rising to the challenge of being a Hero any time the need calls for extraordinary measures.
From routine maintenance to 24/7 emergency repairs, LBA Services has you covered for all your home plumbing, heating, and air conditioning needs. The same goes for new and replacement system installations. Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in North Kansas City, MO.
Recent Jobs and Reviews in North Kansas City, MO
Our Local Reviews by City
- Adrian, MO (2)
- Avondale, MO (1)
- Basehor, KS (21)
- Belton, MO (31)
- Blue Springs, MO (51)
- Bonner Springs, KS (29)
- Buckner, MO (1)
- Bucyrus, KS (6)
- Columbia, MO (1)
- De Soto, KS (20)
- Dearborn, MO (1)
- Edwardsville, KS (14)
- Eudora, KS (9)
- Fairway, KS (86)
- Freeman, MO (1)
- Gardner, KS (14)
- Gladstone, MO (62)
- Grain Valley, MO (24)
- Grandview, MO (66)
- Greenwood, MO (1)
- Houston Lake, MO (7)
- Independence, MO (164)
- Kansas City, KS (380)
- Kansas City, MO (2662)
- Kearney, MO (3)
- Lake Lotawana, MO (4)
- Lake Quivira, KS (17)
- Lake Waukomis, MO (4)
- Lansing, KS (2)
- Lawrence, KS (19)
- Leavenworth, KS (7)
- Leawood, KS (392)
- Lee's Summit, MO (141)
- Lenexa, KS (562)
- Liberty, MO (101)
- Lone Jack, MO (1)
- Louisburg, KS (5)
- Merriam, KS (19)
- Mission, KS (194)
- Mission Hills, KS (73)
- North Kansas City, MO (10)
- Oak Grove, MO (4)
- Odessa, MO (1)
- Olathe, KS (571)
- Ottawa, KS (1)
- Overland Park, KS (1327)
- Parkville, MO (180)
- Peculiar, MO (1)
- Platte City, MO (12)
- Pleasant Hill, MO (1)
- Pleasant Valley, MO (3)
- Prairie Village, KS (499)
- Prairie Village New, KS (2)
- Raymore, MO (23)
- Raytown, MO (70)
- Riverside, MO (15)
- Roeland Park, KS (174)
- Shawnee, KS (963)
- Smithville, MO (1)
- Spring Hill, KS (11)
- Stilwell, KS (59)
- Sugar Creek, MO (6)
- Weatherby Lake, MO (26)
- Wellsville, KS (1)
- Westwood, KS (25)
- Westwood Hills, KS (16)
Job Locations and Reviews
This morning I arrived and Shannon directed me to the two unit heaters that were not functioning. The first unit would not hold the pilot light and the thermocouple was tested and replaced. The unit heater returned to normal function after the repair. The second unit heater held a pilot light and function normally. It was not functioning today due to the gas having been turned off in the past and the pilot light needed relit. This unit heater is a reznor and is located in the bay door area of the shop. Both of the unit heaters today were checked for proper draft, heat exchanger health, fan motor bearing wear and each was cycled on and off after they were back in service. While they are in good condition I do recommend a carbon monoxide detector in the occupied areas due to the age of the equipment. Thank you, Jon Tech notes: new t-couple Dayton//S/N C7942790. Reznor, relit pilot, in the bay door area
Found gas leak on unit heater. Tightened gas leak and ran system checked for any more gas leaks and found none. Checked all rtus for gas leaks and found no leaks at this time. All units are running. Checked with customer to verify there is no more gas smell they didn’t smell anything and systems have been running for 2 hrs.
Today two unit heaters had a gas line fitting replaced. The Northeast unit heater had a 1 1/4” to 1” elbow replaced. The unit heater next to the office had a 1” to 3/4” reducer replaced. These fittings were requested to be replaced by Matt. Previously the gas to all of the building had been turned off by the gas company due to the N.E. Unit having a leak that was before the unit’s gas shut-off. Matt will be contacting spire to return and perform a pressure check on the building’s gas lines due their shut-down of the whole building. I did advise Matt how to reset the units at the breaker box and the hanging unit heater’s (3) equipment switches. Thank you, Jon Tech notes: client supplied fittings were used. The heat exchangers were checked on both units.
Unit heater 1 Model number: LF24-250A-5 Serial number: 5613E01258 Ran gas leak detector over all gas joints on system found no gas leaks. Checked flue pipe and heat exchanger no holes or cracks system is functioning properly at this time. Unit heater 2 Model number: LF25-250A-1 Serial number: 5619K10305 Ran gas leak detector over all gas joints on system found no gas leaks. Checked flue pipe and heat exchanger no holes or cracks system is functioning properly at this time. Unit heater 3 Model number: LF24-250A-5 Serial number: 5613E01259 Ran gas leak detector over all gas joints on system found no gas leaks. Checked flue pipe and heat exchanger no holes or cracks system is functioning properly at this time
Fixed filter slot
80% downflow with double bay return
Arrived to do a performance maintenance. Set up for combustion analysis and static pressure tests. Found that the system is operating with failing static pressure. Reached out to a field supervisor to provide up to date pricing on static pressure repairs. Verified operation of all mechanical and electronic components in the furnace. Cleaned the flame sensor and retested its performance. Checked blower for cleanliness and to see if there is any play in the bearings. Found that the blower wheel is heavily coated in debris. Checked systems heat exchanger to ensure proper venting of flue gas. Found that the heat exchanger is heat stressed, showing hot spots. Checked for carbon monoxide in the air stream. Performed an electronic gas leak search. Spoke with homeowner about the system. Furnace is operational at this time.
Sold
Static decline
Follow up set for tomorrow
Arrived to do a performance maintenance. Started inspection inside and measured a temperature split between return and supply air. Measured power consumption of the blower motor and checked system for cleanliness. Found that the evaporator coil is heavily coated in bacterial growth. Performed a static pressure test and found that the system is operating beyond manufacturers specifications. Adjusted fan speed to the proper setting and found the system is still operating with failing static pressure. Reached out to a field supervisor to finish the diagnosis on the systems static pressure. Went outside and verified system refrigerant charge. Verified operation of all mechanical and electronic components of the condenser. Rinsed condenser coil free of debris. Spoke with homeowner about the system. Air conditioning system is operational at this time.
Completed heating maintenance for RTU 1,3,4, and 5 RTU 1 was frozen up on the second circuit. I recommend leak search. Model number for RTU 1 is KGA120S4BH3Y and serial number is 5613K04858. RTU 2 was not able to complete heating maintenance due to major electrical issues. Model number for RTU 2 is KGA150S4BH2Y and serial number is 5613K4892 RTU 3 has a leak in refrigerant. Recommend leak search. Model number for RTU 3 is KGBP124S4DW1P and serial number is 5617D03992
Need to return to figure out why we have 240 volt to w2 that fried the the board and thermostat
Na
Upon arrival I began the AC tune up. First, I did a static pressure test on the system. The manufacturer has the system rated for a maximum static pressure of .5 and the test on your system is reading at .68 which is failing over the max rating. I then checked the running amps on the blower motor which was within specifications. The blower wheel looked pretty clean to me. The temperature split in the home is at 20 degrees which is within specs. I then went to the outdoor unit and cleaned all the cottonwood off the unit. Then I checked the refrigerant charge and it looks great.the charge is well within specifications. The running amps on the compressor and fan motor are both within specs. The dual run capacitor is within specs on both sides. This system is cooling the home properly at this time. Homeowner opted to sign up for the new SmartAC Family Club Membership. Paid via card in the amount of $228.00. Field supervisor Scott is arrived and taking over the call from here. Have a great
Indoor Air Purification System Installation: Collaborating with a residential client to enhance indoor air quality, we conducted a thorough assessment of their home's needs and preferences. After careful consideration, we selected an advanced purification system designed to reduce allergens and contaminants. Our skilled technicians seamlessly integrated the system with the existing HVAC setup, strategically placing it for optimal effectiveness. Rigorous testing confirmed the system's seamless operation, providing the homeowner with improved indoor air quality for enhanced well-being.
Rebuild lavatory faucet
Arrived at property it was greeted by homeowner, came out today to scope the mainline and provide options for repair or replacement
Arrived at property it was greeted by homeowner, came out today to scope the mainline and provide options for repair or replacement
Arrived at property it was greeted by homeowner, came out today to scope the mainline and provide options for repair or replacement
Arrived at property it was greeted by homeowner, came out today to scope the mainline and provide options for repair or replacement
Arrived. Customer explained that the toilet was clogged and wouldn’t flush. Upon inspection of the toilet wouldn’t flush but it would not go all the way down. Attempted to run toilet auger but wasn’t able to reach the clog. Call customer and explained that I needed to pull the toilet in order to get my auger down the drain line. Customer approved pull and reset fee and I went ahead and pull the toilet off and ran 300 down the toilet line clearing the blockage. Put toilet back on and flushed four or five times with no issues line is open. And flowing. Customer informed me of a crack on the back of the toilet that have been there prior to me being there and the crack was letting water seep out. Use the toilet wax to seal crack in the back of the toilet and customer stated he was going to go out and get a toilet and install it today other than that everything else is good
Arrived. Customer explained that one of their Break room sink was not draining properly. Upon inspection after about a minute I’m running to sync it would fill up and drain very slowly. Drained water and unhooked trap and ran backpack auger about 50 to 60 feet into the drain line and clearing the blockage. Hook trap back up and ran hot water down the sink for about 15 minutes with no back ups occurring. Line is open in flowing
No answer
Checked all operations in the cooling mode and inspected the furnace filter. Checked the static pressure and found it was failing at this time. Checked all electrical and refrigerant components in the system. Today we found the capacitor was failing the refrigerant levels were off and the unit had gotten pretty dirty. We were unable to get with homeowner to go over the issues and repair cost at this time.